All citations for Allure Of Zion

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Allure Of Zion

Last standard health inspection on record

July 12, 2024

This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.

Showing 1 to 11 of 11 citations

  1. No harm, with potential for more than minimal harm

    Establish policies and procedures for medical documentation.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0023, Emergency Preparedness Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 26, 2024).

  2. No harm, with potential for more than minimal harm

    Establish roles under a Waiver declared by secretary.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0026, Emergency Preparedness Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 26, 2024).

  3. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  4. No harm, with potential for more than minimal harm

    Install a two-hour-resistant firewall separation.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0133, Construction Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 29, 2024).

  5. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  6. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 26, 2024).

  7. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  8. No harm, with potential for more than minimal harm

    Have elevators that firefighters can control in the event of a fire.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0531, Services Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 27, 2024).

  9. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  10. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2024).

  11. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 26, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.