All citations for Alta Rehab at Wauconda
State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.
Last standard health inspection on record
August 21, 2024
This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.
Showing 26 to 50 of 77 citations
No harm, with potential for more than minimal harm
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.
The home gave a date the problem would be corrected (July 11, 2022).
No harm, with potential for more than minimal harm
Install emergency lighting that can last at least 1 1/2 hours.
The home gave a date the problem would be corrected (July 22, 2022).
No harm, with potential for more than minimal harm
Have approved installation, maintenance and testing program for fire alarm systems.
The home gave a date the problem would be corrected (July 25, 2022).
No harm, with potential for more than minimal harm
Inspect, test, and maintain automatic sprinkler systems.
The home gave a date the problem would be corrected (July 14, 2022).
No harm, with potential for more than minimal harm
Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.
The home gave a date the problem would be corrected (July 1, 2022).
No harm, with potential for more than minimal harm
Provide a written emergency evacuation plan.
The home gave a date the problem would be corrected (July 18, 2022).
No harm, with potential for more than minimal harm
Have simulated fire drills held at unexpected times.
The home gave a date the problem would be corrected (July 21, 2022).
No harm, with potential for more than minimal harm
Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.
The home gave a date the problem would be corrected (July 22, 2022).
No harm, with potential for more than minimal harm
Ensure that personnel concerned with handling of medical gases and cylinders are trained on the risk.
The home gave a date the problem would be corrected (July 22, 2022).
No harm, with potential for more than minimal harm
Keep aisles, corridors, and exits free of obstruction in case of emergency.
The home gave a date the problem would be corrected (September 9, 2024).
No harm, with potential for more than minimal harm
Have properly located and lighted "Exit" signs.
The home gave a date the problem would be corrected (September 9, 2024).
No harm, with potential for more than minimal harm
Have an enclosure around a vertical opening shaft.
The home gave a date the problem would be corrected (September 9, 2024).
No harm, with potential for more than minimal harm
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
The home gave a date the problem would be corrected (September 9, 2024).
No harm, with potential for more than minimal harm
Install an approved automatic sprinkler system.
The home gave a date the problem would be corrected (September 9, 2024).
No harm, with potential for more than minimal harm
Install corridor and hallway doors that block smoke.
The home gave a date the problem would be corrected (September 9, 2024).
No harm, with potential for more than minimal harm
Ensure proper usage of power strips and extension cords.
The home gave a date the problem would be corrected (September 9, 2024).
No harm, with potential for more than minimal harm
Ensure precautions for handling oxygen cylinders and equipment are correctly followed.
The home gave a date the problem would be corrected (September 9, 2024).
No harm, with potential for more than minimal harm
Provide pharmaceutical services to meet the needs of each resident and employ or obtain the services of a licensed pharmacist.
The home gave a date the problem would be corrected (April 12, 2024).
No harm, with potential for more than minimal harm
Install a two-hour-resistant firewall separation.
The home gave a date the problem would be corrected (August 24, 2023).
No harm, with potential for more than minimal harm
Keep aisles, corridors, and exits free of obstruction in case of emergency.
The home gave a date the problem would be corrected (August 28, 2023).
No harm, with potential for more than minimal harm
Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.
The home gave a date the problem would be corrected (August 25, 2023).
No harm, with potential for more than minimal harm
Have exits that are accessible at all times.
The home gave a date the problem would be corrected (September 25, 2023).
No harm, with potential for more than minimal harm
Have properly located and lighted "Exit" signs.
The home gave a date the problem would be corrected (August 15, 2023).
No harm, with potential for more than minimal harm
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
The home gave a date the problem would be corrected (August 29, 2023).
No harm, with potential for more than minimal harm
Provide properly protected cooking facilities.
The home gave a date the problem would be corrected (August 25, 2023).
Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.