All citations for Autumn Lake Healthcare at Alice Manor

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Autumn Lake Healthcare at Alice Manor

Last standard health inspection on record

April 17, 2026

Showing 1 to 14 of 14 citations

  1. No harm, with potential for more than minimal harm

    Establish an Emergency Preparedness Program (EP).

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0001, Emergency Preparedness Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  2. No harm, with potential for more than minimal harm

    Use approved construction type or materials.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0161, Construction Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 3, 2025).

  3. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  4. No harm, with potential for more than minimal harm

    Properly provide smoke detection systems in areas open to corridors.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0347, Smoke Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  5. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  6. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  7. No harm, with potential for more than minimal harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0914, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  8. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  9. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  10. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  11. No harm, with potential for more than minimal harm

    Have restrictions on the use of portable space heaters.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0781, Miscellaneous Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  12. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

  13. No harm, with potential for more than minimal harm

    Have correct number of accessible exits for each story.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0241, Egress Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 3, 2025).

  14. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 11, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.