All citations for Bria of Westmont

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Bria of Westmont

Last standard health inspection on record

November 21, 2025

Showing 1 to 11 of 11 citations

  1. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 13, 2025).

  2. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 12, 2025).

  3. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 13, 2025).

  4. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 14, 2025).

  5. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 15, 2025).

  6. No harm, with potential for more than minimal harm

    Install a fire alarm system that can be heard throughout the facility.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0341, Smoke Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 13, 2025).

  7. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 19, 2025).

  8. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 12, 2025).

  9. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 13, 2025).

  10. No harm, with potential for more than minimal harm

    Ensure that gas fire places are out of the reach of patients and can be shut off if unit is working improperly.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0524, Services Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 15, 2025).

  11. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of November 21, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 13, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.