  1. No harm, with potential for more than minimal harm

    Establish policies and procedures for volunteers.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0024, Emergency Preparedness Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 28, 2025).

  2. No harm, with potential for more than minimal harm

    Conduct testing and exercise requirements.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0039, Emergency Preparedness Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 20, 2025).

  3. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 20, 2025).

  4. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 20, 2025).

  5. No harm, with potential for more than minimal harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0914, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 30, 2025).

  6. No harm, with potential for more than minimal harm

    Have a battery powered remote alarm panel in a location accessible by operating personnel.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0916, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 30, 2025).

  7. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 25, 2025).

  8. No harm, with potential for more than minimal harm

    Ensure that testing and maintenance of electrical equipment is performed.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0921, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 30, 2025).

  9. No harm, with potential for more than minimal harm

    Have corridors or aisles that are unobstructed and are at least 8 feet in width.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0232, Egress Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 7, 2025).

  10. No harm, with potential for more than minimal harm

    Have properly located and lighted "Exit" signs.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0293, Egress Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 20, 2025).

  11. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 20, 2025).

  12. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of March 6, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 20, 2025).