All citations for Centennial Healthcare and Rehabilitation Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Centennial Healthcare and Rehabilitation Center

Last standard health inspection on record

July 2, 2026

Showing 1 to 8 of 8 citations

  1. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of August 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 1, 2025).

  2. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of August 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 1, 2025).

  3. No harm, with potential for more than minimal harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0914, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 1, 2025).

  4. No harm, with potential for more than minimal harm

    Have an enclosure around a vertical opening shaft.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0311, Smoke Deficiencies. Inspection of August 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 1, 2025).

  5. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of August 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 1, 2025).

  6. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of August 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 1, 2025).

  7. No harm, with potential for minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of August 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 1, 2025).

  8. No harm, with potential for minimal harm

    Develop a communication plan.

    Pattern (more than a few residents). CMS level B.

    Emergency preparedness citation E-0029, Emergency Preparedness Deficiencies. Inspection of August 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 1, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.