All citations for Civita Care Meadowbrook

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Civita Care Meadowbrook

Last standard health inspection on record

December 2, 2025

Showing 1 to 8 of 8 citations

  1. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of January 23, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

  2. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 23, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

  3. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of January 23, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

  4. No harm, with potential for more than minimal harm

    Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0362, Smoke Deficiencies. Inspection of January 23, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

  5. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of January 23, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

  6. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of January 23, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

  7. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 23, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

  8. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 23, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.