All citations for Complete Care at Corsica Hills LLC

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Complete Care at Corsica Hills LLC

Last standard health inspection on record

January 12, 2026

Showing 1 to 9 of 9 citations

  1. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

  2. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

  3. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

  4. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

  5. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

  6. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

  7. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

  8. No harm, with potential for more than minimal harm

    Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0362, Smoke Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

  9. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0511, Services Deficiencies. Inspection of January 12, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 12, 2026).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.