All citations for Complete Care at Maple Grove LLC
State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.
Last standard health inspection on record
July 2, 2026
Showing 1 to 14 of 14 citations
No harm, with potential for more than minimal harm
Develop and maintain an Emergency Preparedness Program (EP).
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Conduct risk assessment and an All-Hazards approach.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Conduct testing and exercise requirements.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Inspect, test, and maintain automatic sprinkler systems.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Properly select, install, inspect, or maintain portable fire extinguishes.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Have generator or other power source capable of supplying service within 10 seconds.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Construct fire resistant interior walls.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Install corridor and hallway doors that block smoke.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Have power receptacles that are properly grounded.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Meet requirements for the use of electrical equipment.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Install an approved automatic sprinkler system.
The home gave a date the problem would be corrected (June 24, 2025).
No harm, with potential for more than minimal harm
Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.
The home gave a date the problem would be corrected (June 24, 2025).
Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.