All citations for Crestview Court

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Crestview Court

Last standard health inspection on record

June 18, 2026

Showing 1 to 6 of 6 citations

  1. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of March 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 22, 2024).

  2. No harm, with potential for more than minimal harm

    Have properly installed hallway dispensers for alcohol-based hand rub.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0325, Smoke Deficiencies. Inspection of March 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 22, 2024).

  3. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of March 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 22, 2024).

  4. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of March 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 22, 2024).

  5. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of March 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 22, 2024).

  6. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of March 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 22, 2024).