All citations for Current River Rehabilitation & Health Care Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Current River Rehabilitation & Health Care Center

Last standard health inspection on record

August 29, 2025

Showing 1 to 5 of 5 citations

  1. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of February 9, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 26, 2023).

  2. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of February 9, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 26, 2023).

  3. No harm, with potential for more than minimal harm

    Have restrictions on the use of portable space heaters.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0781, Miscellaneous Deficiencies. Inspection of February 9, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 26, 2023).

  4. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 9, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 26, 2023).

  5. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 9, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 26, 2023).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.