All citations for Eastern Plumas Hospital- Portola Campus DP/SNF

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Eastern Plumas Hospital- Portola Campus DP/SNF

Last standard health inspection on record

July 24, 2025

Showing 1 to 8 of 8 citations

  1. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0521, Services Deficiencies. Inspection of July 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2025).

  2. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of July 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 20, 2025).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of July 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 20, 2025).

  4. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of July 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 20, 2025).

  5. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 25, 2025).

  6. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 25, 2025).

  7. No harm, with potential for minimal harm

    Have a fire alarm with audible and visual signals that transmits the alarm automatically to notify emergency forces in event of fire.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0343, Smoke Deficiencies. Inspection of July 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 20, 2025).

  8. No harm, with potential for minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of July 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 20, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.