All citations for Good Shepherd Village

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Good Shepherd Village

Last standard health inspection on record

June 30, 2026

Showing 26 to 39 of 39 citations

  1. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0521, Services Deficiencies. Inspection of December 19, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 21, 2023).

  2. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of December 19, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 21, 2023).

  3. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of December 19, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 21, 2023).

  4. No harm, with potential for more than minimal harm

    Provide at least two remote exits on each floor or fire section of the building.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0252, Egress Deficiencies. Inspection of June 30, 2026. Found during a standard inspection.

    The home has a plan to correct it (August 28, 2026).

  5. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of June 30, 2026. Found during a standard inspection.

    The home has a plan to correct it (August 28, 2026).

  6. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of June 30, 2026. Found during a standard inspection.

    The home has a plan to correct it (August 28, 2026).

  7. No harm, with potential for more than minimal harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0222, Egress Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 2, 2025).

  8. No harm, with potential for more than minimal harm

    Provide at least two remote exits on each floor or fire section of the building.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0252, Egress Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home has a plan to correct it (June 9, 2025).

  9. No harm, with potential for more than minimal harm

    Have properly located and lighted "Exit" signs.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0293, Egress Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 2, 2025).

  10. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 2, 2025).

  11. No harm, with potential for more than minimal harm

    Properly install and monitor supervisory attachments on automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0352, Smoke Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 2, 2025).

  12. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 2, 2025).

  13. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of December 19, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 21, 2023).

  14. No harm, with potential for more than minimal harm

    Ensure operating rooms are properly protected and written records are maintained and available for inspection.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0913, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 1, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 2, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.