All citations for Hadley Pointe Nursing Rehab & Care

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Hadley Pointe Nursing Rehab & Care

Last standard health inspection on record

April 22, 2026

Showing 1 to 11 of 11 citations

  1. No harm, with potential for more than minimal harm

    Conduct testing and exercise requirements.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0039, Emergency Preparedness Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 6, 2025).

  2. No harm, with potential for more than minimal harm

    Have an enclosure around a vertical opening shaft.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0311, Smoke Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 6, 2025).

  3. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 5, 2025).

  4. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0521, Services Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 5, 2025).

  5. No harm, with potential for more than minimal harm

    Have exits that are accessible at all times.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0271, Egress Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 27, 2025).

  6. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 6, 2025).

  7. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 5, 2025).

  8. No harm, with potential for more than minimal harm

    Provide a written emergency evacuation plan.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0711, Miscellaneous Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 5, 2025).

  9. No harm, with potential for more than minimal harm

    Meet requirements for the installation and maintenance of electrical systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0911, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 27, 2025).

  10. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 5, 2025).

  11. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of January 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 5, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.