All citations for Hillcrest Firethorn

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Hillcrest Firethorn

Last standard health inspection on record

August 6, 2026

Showing 1 to 8 of 8 citations

  1. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of August 6, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 17, 2026).

  2. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of August 6, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 17, 2026).

  3. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of August 6, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 17, 2026).

  4. No harm, with potential for more than minimal harm

    Meet other general requirements that are deficient.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0500, Services Deficiencies. Inspection of August 6, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 17, 2026).

  5. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 6, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 17, 2026).

  6. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 6, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 17, 2026).

  7. No harm, with potential for more than minimal harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0222, Egress Deficiencies. Inspection of August 6, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 17, 2026).

  8. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 6, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 17, 2026).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.