All citations for Los Banos Post Acute

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Los Banos Post Acute

Last standard health inspection on record

August 8, 2025

Showing 1 to 9 of 9 citations

  1. No harm, with potential for more than minimal harm

    Conduct testing and exercise requirements.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0039, Emergency Preparedness Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 19, 2025).

  2. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 19, 2025).

  3. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0521, Services Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 5, 2025).

  4. No harm, with potential for more than minimal harm

    Use approved construction type or materials.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0161, Construction Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 22, 2025).

  5. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 18, 2025).

  6. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2025).

  7. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 22, 2025).

  8. No harm, with potential for minimal harm

    Provide primary/alternate means for communication.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0032, Emergency Preparedness Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 29, 2025).

  9. No harm, with potential for minimal harm

    Install a fire alarm system that can be heard throughout the facility.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0341, Smoke Deficiencies. Inspection of August 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 20, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.