All citations for Meramec Nursing

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Meramec Nursing

Last standard health inspection on record

November 22, 2024

Showing 1 to 11 of 11 citations

  1. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  2. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  3. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  4. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  5. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  6. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  7. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  8. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  9. No harm, with potential for more than minimal harm

    Meet requirements for the installation and maintenance of electrical systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0911, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  10. No harm, with potential for more than minimal harm

    Ensure that personnel concerned with handling of medical gases and cylinders are trained on the risk.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0926, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

  11. No harm, with potential for more than minimal harm

    Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0741, Miscellaneous Deficiencies. Inspection of June 16, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 30, 2022).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.