All citations for New Glarus Home

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to New Glarus Home

Last standard health inspection on record

March 19, 2026

Showing 1 to 13 of 13 citations

  1. No harm, with potential for more than minimal harm

    Develop and maintain an Emergency Preparedness Program (EP).

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0004, Emergency Preparedness Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 9, 2026).

  2. No harm, with potential for more than minimal harm

    Conduct risk assessment and an All-Hazards approach.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0006, Emergency Preparedness Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 9, 2026).

  3. No harm, with potential for more than minimal harm

    Develop Emergency Preparedness policies and procedures.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0013, Emergency Preparedness Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 9, 2026).

  4. No harm, with potential for more than minimal harm

    Create arrangements with other facilities to receive patients.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0025, Emergency Preparedness Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 6, 2026).

  5. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 24, 2026).

  6. No harm, with potential for more than minimal harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0222, Egress Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 1, 2026).

  7. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 3, 2026).

  8. No harm, with potential for more than minimal harm

    Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0362, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 20, 2026).

  9. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 20, 2026).

  10. No harm, with potential for more than minimal harm

    Construct fire resistant interior walls.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0331, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 20, 2026).

  11. No harm, with potential for more than minimal harm

    Properly provide smoke detection systems in areas open to corridors.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0347, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 13, 2026).

  12. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 20, 2026).

  13. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 20, 2026).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.