All citations for Northeast Ctr for Rehabilitation and Brain Injury

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Northeast Ctr for Rehabilitation and Brain Injury

Last standard health inspection on record

November 21, 2024

Showing 1 to 12 of 12 citations

  1. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 23, 2025).

  2. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 23, 2025).

  3. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 8, 2025).

  4. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 23, 2025).

  5. No harm, with potential for more than minimal harm

    Have elevators that firefighters can control in the event of a fire.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0531, Services Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    No plan of correction on record.

  6. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 27, 2024).

  7. No harm, with potential for more than minimal harm

    Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0901, Electrical Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 23, 2025).

  8. No harm, with potential for more than minimal harm

    Have proper power supply for life support equipment.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0915, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 23, 2025).

  9. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 23, 2025).

  10. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    No plan of correction on record.

  11. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 23, 2025).

  12. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of November 21, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 23, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.