All citations for Oak Park Care Center
State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.
Last standard health inspection on record
August 14, 2024
This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.
Showing 1 to 25 of 30 citations
No harm, with potential for more than minimal harm
Develop and maintain an Emergency Preparedness Program (EP).
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Address subsistence needs for staff and patients.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
List the names and contact information of those in the facility.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Conduct testing and exercise requirements.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Have approved installation, maintenance and testing program for fire alarm systems.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Inspect, test, and maintain automatic sprinkler systems.
A waiver was granted (March 8, 2023).
No harm, with potential for more than minimal harm
Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Properly select, install, inspect, or maintain portable fire extinguishes.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
The home gave a date the problem would be corrected (March 16, 2023).
No harm, with potential for more than minimal harm
Have properly installed electrical wiring and gas equipment.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.
A waiver was granted (March 8, 2023).
No harm, with potential for more than minimal harm
Provide a written emergency evacuation plan.
The home gave a date the problem would be corrected (March 16, 2023).
No harm, with potential for more than minimal harm
Have simulated fire drills held at unexpected times.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.
The home gave a date the problem would be corrected (March 17, 2023).
No harm, with potential for more than minimal harm
Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Ensure proper usage of power strips and extension cords.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Ensure that testing and maintenance of electrical equipment is performed.
The home gave a date the problem would be corrected (March 17, 2023).
No harm, with potential for more than minimal harm
Use approved construction type or materials.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Keep aisles, corridors, and exits free of obstruction in case of emergency.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.
The home gave a date the problem would be corrected (March 16, 2023).
No harm, with potential for more than minimal harm
Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Install emergency lighting that can last at least 1 1/2 hours.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Have properly located and lighted "Exit" signs.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
The home gave a date the problem would be corrected (March 8, 2023).
No harm, with potential for more than minimal harm
Provide properly protected cooking facilities.
The home gave a date the problem would be corrected (March 8, 2023).
Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.