All citations for Optalis Health and Rehabilitation of Three Rivers

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Optalis Health and Rehabilitation of Three Rivers

Last standard health inspection on record

December 3, 2025

Showing 1 to 12 of 12 citations

  1. No harm, with potential for more than minimal harm

    Develop and maintain an Emergency Preparedness Program (EP).

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0004, Emergency Preparedness Deficiencies. Inspection of April 2, 2026. Found during a complaint inspection.

    The home gave a date the problem would be corrected (April 24, 2026).

  2. No harm, with potential for more than minimal harm

    Address subsistence needs for staff and patients.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0015, Emergency Preparedness Deficiencies. Inspection of April 2, 2026. Found during a complaint inspection.

    The home gave a date the problem would be corrected (May 15, 2026).

  3. No harm, with potential for more than minimal harm

    Establish staff and initial training requirements.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0037, Emergency Preparedness Deficiencies. Inspection of April 2, 2026. Found during a complaint inspection.

    The home gave a date the problem would be corrected (April 24, 2026).

  4. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of April 1, 2026. Found during a complaint inspection.

    The home gave a date the problem would be corrected (August 17, 2026).

  5. No harm, with potential for more than minimal harm

    Address subsistence needs for staff and patients.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0015, Emergency Preparedness Deficiencies. Inspection of December 3, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 12, 2026).

  6. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of December 3, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 12, 2026).

  7. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of December 3, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 12, 2026).

  8. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of December 3, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 12, 2026).

  9. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0521, Services Deficiencies. Inspection of December 3, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 16, 2026).

  10. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of April 1, 2026. Found during a complaint inspection.

    The home gave a date the problem would be corrected (April 30, 2026).

  11. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of December 3, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 12, 2026).

  12. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of December 3, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 12, 2026).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.