All citations for Pickaway Manor Care Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Pickaway Manor Care Center

Last standard health inspection on record

January 29, 2026

Showing 1 to 13 of 13 citations

  1. No harm, with potential for more than minimal harm

    Meet requirements for sections of health care facilities separated by fire resistive construction.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0131, Construction Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

  2. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 28, 2022).

  3. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 28, 2022).

  4. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

  5. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

  6. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0511, Services Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

  7. No harm, with potential for more than minimal harm

    Provide a written emergency evacuation plan.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0711, Miscellaneous Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

  8. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

  9. No harm, with potential for more than minimal harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0914, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

  10. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 28, 2022).

  11. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

  12. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 28, 2022).

  13. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of November 8, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 30, 2021).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.