State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Riverside

Last standard health inspection on record

January 15, 2026

Showing 1 to 7 of 7 citations

  1. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0521, Services Deficiencies. Inspection of January 15, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  2. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of January 15, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  3. No harm, with potential for more than minimal harm

    Have power receptacles that are properly grounded.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0912, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 15, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  4. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of January 15, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  5. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 15, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  6. No harm, with potential for more than minimal harm

    Have proper fire barriers, ventilation and signs for the transfilling of oxygen.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0927, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 15, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

  7. No harm, with potential for minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of January 15, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 12, 2026).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.