All citations for Sans Souci Rehabilitation And Nursing Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Sans Souci Rehabilitation And Nursing Center

Last standard health inspection on record

August 14, 2024

This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.

Showing 1 to 10 of 10 citations

  1. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  2. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  3. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  4. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  5. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  6. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0511, Services Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  7. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0521, Services Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  8. No harm, with potential for more than minimal harm

    Ensure that testing and maintenance of electrical equipment is performed.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0921, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  9. No harm, with potential for minimal harm

    Provide family notifications of emergency plan.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0035, Emergency Preparedness Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

  10. No harm, with potential for minimal harm

    Implement emergency and standby power systems.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0041, Emergency Preparedness Deficiencies. Inspection of August 7, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 5, 2018).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.