All citations for Spokane Valley Health and Rehabilitation of Cascad
State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.
Last standard health inspection on record
November 24, 2025
Showing 26 to 35 of 35 citations
No harm, with potential for more than minimal harm
Ensure that the resident and his/her doctor meet face-to-face at all required visits.
The home gave a date the problem would be corrected (September 24, 2024).
No harm, with potential for more than minimal harm
Observe each nurse aide's job performance and give regular training.
The home gave a date the problem would be corrected (September 24, 2024).
No harm, with potential for more than minimal harm
Ensure each resident must receive and the facility must provide necessary behavioral health care and services.
The home gave a date the problem would be corrected (September 24, 2024).
No harm, with potential for more than minimal harm
Ensure medication error rates are not 5 percent or greater.
The home gave a date the problem would be corrected (September 24, 2024).
No harm, with potential for more than minimal harm
Ensure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs.
The home gave a date the problem would be corrected (September 24, 2024).
No harm, with potential for more than minimal harm
Provide sufficient support personnel to safely and effectively carry out the functions of the food and nutrition service.
The home gave a date the problem would be corrected (September 24, 2024).
No harm, with potential for more than minimal harm
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.
The home gave a date the problem would be corrected (September 24, 2024).
No harm, with potential for more than minimal harm
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
The home gave a date the problem would be corrected (September 11, 2024).
No harm, with potential for more than minimal harm
Properly select, install, inspect, or maintain portable fire extinguishes.
The home gave a date the problem would be corrected (September 11, 2024).
No harm, with potential for more than minimal harm
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
The home gave a date the problem would be corrected (September 11, 2024).
Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.