All citations for St. Elizabeth Rehabilitation & Nursing Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to St. Elizabeth Rehabilitation & Nursing Center

Last standard health inspection on record

February 26, 2026

Showing 1 to 14 of 14 citations

  1. No harm, with potential for more than minimal harm

    Establish roles under a Waiver declared by secretary.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0026, Emergency Preparedness Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  2. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  4. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  5. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  6. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  7. No harm, with potential for more than minimal harm

    Ensure that testing and maintenance of electrical equipment is performed.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0921, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  8. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  9. No harm, with potential for more than minimal harm

    Install proper backup exit lighting.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0281, Egress Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  10. No harm, with potential for more than minimal harm

    Have properly located and lighted "Exit" signs.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0293, Egress Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  11. No harm, with potential for more than minimal harm

    Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0362, Smoke Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  12. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  13. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

  14. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 26, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 14, 2026).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.