All citations for Taylorville SKLD Nur & Rehab

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Taylorville SKLD Nur & Rehab

Last standard health inspection on record

June 4, 2026

Showing 26 to 30 of 30 citations

  1. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of February 1, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 23, 2024).

  2. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of February 1, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 23, 2024).

  3. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 1, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 23, 2024).

  4. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 1, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 23, 2024).

  5. No harm, with potential for more than minimal harm

    Ensure proper storage of liquid oxygen.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0930, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 1, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 23, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.