All citations for Westchester Center For Rehabilitation & Nursing

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Westchester Center For Rehabilitation & Nursing

Last standard health inspection on record

January 29, 2025

Showing 1 to 12 of 12 citations

  1. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 14, 2019).

  2. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0521, Services Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 10, 2019).

  3. No harm, with potential for more than minimal harm

    Have elevators that firefighters can control in the event of a fire.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0531, Services Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 10, 2019).

  4. No harm, with potential for more than minimal harm

    Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0901, Electrical Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 13, 2019).

  5. No harm, with potential for more than minimal harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0914, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 14, 2019).

  6. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 14, 2019).

  7. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 13, 2019).

  8. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 14, 2019).

  9. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 13, 2019).

  10. No harm, with potential for more than minimal harm

    Have a battery powered remote alarm panel in a location accessible by operating personnel.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0916, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 13, 2019).

  11. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 13, 2019).

  12. No harm, with potential for minimal harm

    Provide a means of sharing information on occupancy/needs.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0034, Emergency Preparedness Deficiencies. Inspection of July 17, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 13, 2019).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.