All citations for Willow Grove Post Acute

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Willow Grove Post Acute

Last standard health inspection on record

May 15, 2026

Showing 1 to 7 of 7 citations

  1. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of January 19, 2024. Found during a complaint inspection.

    The home gave a date the problem would be corrected (March 2, 2024).

  2. No harm, with potential for more than minimal harm

    Install resident room doors of proper design and width.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0233, Egress Deficiencies. Inspection of August 15, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 2, 2024).

  3. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of August 15, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 2, 2024).

  4. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of August 15, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 2, 2024).

  5. No harm, with potential for more than minimal harm

    Ensure gas cylinders are properly stored.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0906, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 15, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 2, 2024).

  6. No harm, with potential for minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of August 15, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 2, 2024).

  7. No harm, with potential for minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0521, Services Deficiencies. Inspection of January 19, 2024. Found during a complaint inspection.

    The home gave a date the problem would be corrected (March 2, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.