All citations for Applewood Nursing Center, Inc

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Applewood Nursing Center, Inc

Last standard health inspection on record

April 17, 2025

Showing 1 to 25 of 29 citations

  1. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of April 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 12, 2025).

  2. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of April 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 12, 2025).

  3. No harm, with potential for more than minimal harm

    Have a complete alarm system manually initiated and initiated by fire sprinkler system connection.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0342, Smoke Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  4. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  5. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0521, Services Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  6. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  7. No harm, with potential for more than minimal harm

    Implement emergency and standby power systems.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0041, Emergency Preparedness Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  8. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  9. No harm, with potential for more than minimal harm

    Install a fire alarm system that can be heard throughout the facility.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0341, Smoke Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  10. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  11. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  12. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  13. No harm, with potential for more than minimal harm

    Provide a written emergency evacuation plan.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0711, Miscellaneous Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  14. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  15. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

  16. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of April 17, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 12, 2025).

  17. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  18. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  19. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  20. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  21. No harm, with potential for more than minimal harm

    Ensure that corridors are separated from use areas by walls constructed to limit the passage of smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0362, Smoke Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  22. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  23. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  24. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 3, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 4, 2024).

  25. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of March 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2023).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.