All citations for Arbor View Care Center, LLC

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Arbor View Care Center, LLC

Last standard health inspection on record

July 30, 2024

This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.

Showing 1 to 13 of 13 citations

  1. No harm, with potential for more than minimal harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0222, Egress Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  2. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  3. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  4. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 26, 2024).

  5. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of March 16, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 9, 2023).

  6. No harm, with potential for more than minimal harm

    Install proper backup exit lighting.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0281, Egress Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  7. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  8. No harm, with potential for more than minimal harm

    Provide large enough exits.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0231, Egress Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  9. No harm, with potential for more than minimal harm

    Follow proper procedures when the fire alarm was out of service for more than 4 hours.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0346, Smoke Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  10. No harm, with potential for more than minimal harm

    Follow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0354, Smoke Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  11. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  12. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

  13. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 30, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 25, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.