All citations for Brian Center of Fincastle
State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.
Last standard health inspection on record
August 18, 2022
This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.
Showing 1 to 17 of 17 citations
No harm, with potential for more than minimal harm
Have approved installation, maintenance and testing program for fire alarm systems.
The home gave a date the problem would be corrected (October 31, 2022).
No harm, with potential for more than minimal harm
Inspect, test, and maintain automatic sprinkler systems.
The home gave a date the problem would be corrected (October 31, 2022).
No harm, with potential for more than minimal harm
Install corridor and hallway doors that block smoke.
The home gave a date the problem would be corrected (October 31, 2022).
No harm, with potential for more than minimal harm
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
The home gave a date the problem would be corrected (October 31, 2022).
No harm, with potential for more than minimal harm
Use approved construction type or materials.
The home gave a date the problem would be corrected (April 10, 2019).
No harm, with potential for more than minimal harm
Have approved installation, maintenance and testing program for fire alarm systems.
The home gave a date the problem would be corrected (April 10, 2019).
No harm, with potential for more than minimal harm
Install smoke barrier doors that can resist smoke for at least 20 minutes.
The home gave a date the problem would be corrected (April 10, 2019).
No harm, with potential for more than minimal harm
Have generator or other power source capable of supplying service within 10 seconds.
The home gave a date the problem would be corrected (April 10, 2019).
No harm, with potential for more than minimal harm
Have properly installed electrical wiring and gas equipment.
The home gave a date the problem would be corrected (October 31, 2022).
No harm, with potential for more than minimal harm
Inspect, test, and maintain automatic sprinkler systems.
The home gave a date the problem would be corrected (May 25, 2021).
No harm, with potential for more than minimal harm
Have properly installed electrical wiring and gas equipment.
The home gave a date the problem would be corrected (May 25, 2021).
No harm, with potential for more than minimal harm
Keep aisles, corridors, and exits free of obstruction in case of emergency.
The home gave a date the problem would be corrected (October 31, 2022).
No harm, with potential for more than minimal harm
Have properly located and lighted "Exit" signs.
The home gave a date the problem would be corrected (October 31, 2022).
No harm, with potential for more than minimal harm
Have properly located and lighted "Exit" signs.
The home gave a date the problem would be corrected (May 25, 2021).
No harm, with potential for more than minimal harm
Install corridor and hallway doors that block smoke.
The home gave a date the problem would be corrected (May 25, 2021).
No harm, with potential for more than minimal harm
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
The home gave a date the problem would be corrected (May 25, 2021).
No harm, with potential for more than minimal harm
Meet other general requirements that are deficient.
The home gave a date the problem would be corrected (April 10, 2019).
Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.