All citations for Corona Post Acute Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Corona Post Acute Center

Last standard health inspection on record

April 10, 2026

Showing 1 to 25 of 27 citations

  1. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of January 9, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 24, 2025).

  2. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 9, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 24, 2025).

  3. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 26, 2026).

  4. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 26, 2026).

  5. No harm, with potential for more than minimal harm

    Have power receptacles that are properly grounded.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0912, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 26, 2026).

  6. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 26, 2026).

  7. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of January 9, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 24, 2025).

  8. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 9, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 24, 2025).

  9. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 26, 2026).

  10. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 26, 2026).

  11. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 26, 2026).

  12. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 7, 2026).

  13. No harm, with potential for more than minimal harm

    Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0741, Miscellaneous Deficiencies. Inspection of April 10, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 26, 2026).

  14. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of January 9, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 24, 2025).

  15. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0511, Services Deficiencies. Inspection of January 9, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 24, 2025).

  16. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 9, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 24, 2025).

  17. No harm, with potential for more than minimal harm

    Use approved construction type or materials.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0161, Construction Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

  18. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

  19. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

  20. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

  21. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

  22. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0511, Services Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

  23. No harm, with potential for more than minimal harm

    Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0741, Miscellaneous Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

  24. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

  25. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 17, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2022).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.