State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Cross Keys Village-Brethren Home Community, the

Last standard health inspection on record

March 31, 2026

Showing 1 to 9 of 9 citations

  1. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0511, Services Deficiencies. Inspection of March 13, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 10, 2025).

  2. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of April 4, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 31, 2024).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of April 4, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 31, 2024).

  4. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of March 13, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 10, 2025).

  5. No harm, with potential for more than minimal harm

    Have properly located and lighted "Exit" signs.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0293, Egress Deficiencies. Inspection of March 13, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 10, 2025).

  6. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of March 13, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 10, 2025).

  7. No harm, with potential for more than minimal harm

    Have an enclosure around a vertical opening shaft.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0311, Smoke Deficiencies. Inspection of June 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 19, 2023).

  8. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of June 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 19, 2023).

  9. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of June 29, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 19, 2023).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.