All citations for Dubois Nursing Home

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Dubois Nursing Home

Last standard health inspection on record

April 30, 2026

Showing 1 to 6 of 6 citations

  1. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of June 27, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 12, 2024).

  2. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of May 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 7, 2025).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 15, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 7, 2025).

  4. No harm, with potential for minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of June 27, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 12, 2024).

  5. No harm, with potential for minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of June 27, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 12, 2024).

  6. No harm, with potential for minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level B.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of June 27, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 12, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.