All citations for Eden Vista Prospect Heights

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Eden Vista Prospect Heights

Last standard health inspection on record

December 12, 2025

Showing 1 to 25 of 55 citations

  1. No harm, with potential for more than minimal harm

    Have an alternate power supply for its alarm system.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0344, Smoke Deficiencies. Inspection of August 9, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  2. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of August 9, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of August 9, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  4. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of August 9, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  5. No harm, with potential for more than minimal harm

    Ensure that personnel concerned with handling of medical gases and cylinders are trained on the risk.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0926, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 9, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 21, 2024).

  6. No harm, with potential for more than minimal harm

    Address patient/client population and determine types of services needed.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0007, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 5, 2023).

  7. No harm, with potential for more than minimal harm

    Establish policies and procedures for volunteers.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0024, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  8. No harm, with potential for more than minimal harm

    Provide family notifications of emergency plan.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0035, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  9. No harm, with potential for more than minimal harm

    Establish staff and initial training requirements.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0037, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  10. No harm, with potential for more than minimal harm

    Install a two-hour-resistant firewall separation.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0133, Construction Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  11. No harm, with potential for more than minimal harm

    Have properly located and lighted "Exit" signs.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0293, Egress Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  12. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  13. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    A waiver was granted (July 7, 2023).

  14. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  15. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  16. No harm, with potential for more than minimal harm

    Have a battery powered remote alarm panel in a location accessible by operating personnel.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0916, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    A waiver was granted (September 25, 2023).

  17. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  18. No harm, with potential for more than minimal harm

    Address subsistence needs for staff and patients.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0015, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  19. No harm, with potential for more than minimal harm

    Establish policies and procedures including evacuation.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0020, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  20. No harm, with potential for more than minimal harm

    Create arrangements with other facilities to receive patients.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0025, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  21. No harm, with potential for more than minimal harm

    Provide emergency officials' contact information.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0031, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  22. No harm, with potential for more than minimal harm

    Provide primary/alternate means for communication.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0032, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  23. No harm, with potential for more than minimal harm

    Conduct testing and exercise requirements.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0039, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  24. No harm, with potential for more than minimal harm

    Implement emergency and standby power systems.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0041, Emergency Preparedness Deficiencies. Inspection of May 18, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 15, 2023).

  25. No harm, with potential for more than minimal harm

    Develop Emergency Preparedness policies and procedures.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0013, Emergency Preparedness Deficiencies. Inspection of August 19, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 6, 2022).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.