All citations for Flint Ridge NRSG & Rehab Ctr

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Flint Ridge NRSG & Rehab Ctr

Last standard health inspection on record

May 5, 2025

Showing 1 to 25 of 76 citations

  1. Harm to a resident

    Provide enough food/fluids to maintain a resident's health.

    Isolated (one or a few residents). CMS level G.

    Health citation F-0692, Quality of Life and Care Deficiencies. Inspection of September 11, 2024. Found during a complaint inspection.

    The home gave a date the problem would be corrected (October 3, 2024).

  2. Harm to a resident

    Provide safe, appropriate pain management for a resident who requires such services.

    Isolated (one or a few residents). CMS level G.

    Health citation F-0697, Quality of Life and Care Deficiencies. Inspection of September 11, 2024. Found during a complaint inspection.

    The home gave a date the problem would be corrected (October 3, 2024).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 5, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 27, 2025).

  4. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 5, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 27, 2025).

  5. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of August 17, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 20, 2023).

  6. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of August 17, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 20, 2023).

  7. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of August 17, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 20, 2023).

  8. No harm, with potential for more than minimal harm

    Have proper power supply for life support equipment.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0915, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 17, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 20, 2023).

  9. No harm, with potential for more than minimal harm

    Provide and implement an infection prevention and control program.

    Widespread (many residents). CMS level F.

    Health citation F-0880, Infection Control Deficiencies. Inspection of July 23, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 3, 2021).

  10. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of July 23, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 3, 2021).

  11. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of July 23, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 3, 2021).

  12. No harm, with potential for more than minimal harm

    Provide and implement an infection prevention and control program.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0880, Infection Control Deficiencies. Inspection of September 3, 2025. Found during a complaint inspection.

    The home gave a date the problem would be corrected (September 19, 2025).

  13. No harm, with potential for more than minimal harm

    Ensure food and drink is palatable, attractive, and at a safe and appetizing temperature.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0804, Nutrition and Dietary Deficiencies. Inspection of May 5, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 27, 2025).

  14. No harm, with potential for more than minimal harm

    Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0812, Nutrition and Dietary Deficiencies. Inspection of May 5, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 27, 2025).

  15. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of May 5, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 27, 2025).

  16. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 5, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 27, 2025).

  17. No harm, with potential for more than minimal harm

    Honor the resident's right to a safe, clean, comfortable and homelike environment, including but not limited to receiving treatment and supports for daily living safely.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0584, Resident Rights Deficiencies. Inspection of September 11, 2024. Found during a complaint inspection.

    The home gave a date the problem would be corrected (October 3, 2024).

  18. No harm, with potential for more than minimal harm

    Provide each resident with a nourishing, palatable, well-balanced diet that meets his or her daily nutritional and special dietary needs.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0800, Nutrition and Dietary Deficiencies. Inspection of September 11, 2024. Found during a complaint inspection.

    The home gave a date the problem would be corrected (October 3, 2024).

  19. No harm, with potential for more than minimal harm

    Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0812, Nutrition and Dietary Deficiencies. Inspection of September 11, 2024. Found during a complaint inspection.

    The home gave a date the problem would be corrected (October 3, 2024).

  20. No harm, with potential for more than minimal harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0222, Egress Deficiencies. Inspection of August 17, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 20, 2023).

  21. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of August 17, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 20, 2023).

  22. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of August 17, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 20, 2023).

  23. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 17, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 20, 2023).

  24. No harm, with potential for more than minimal harm

    Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0656, Resident Assessment and Care Planning Deficiencies. Inspection of July 23, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 3, 2021).

  25. No harm, with potential for more than minimal harm

    Use approved construction type or materials.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0161, Construction Deficiencies. Inspection of July 23, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (September 3, 2021).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.