All citations for Glen Haven Health and Rehabilitation, LLC

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Glen Haven Health and Rehabilitation, LLC

Last standard health inspection on record

July 26, 2023

This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.

Showing 1 to 25 of 27 citations

  1. Immediate jeopardy to resident health or safety

    Provide appropriate treatment and care according to orders, resident’s preferences and goals.

    Pattern (more than a few residents). CMS level K.

    Health citation F-0684, Quality of Life and Care Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 24, 2023).

  2. Immediate jeopardy to resident health or safety

    Set up an ongoing quality assessment and assurance group to review quality deficiencies and develop corrective plans of action.

    Pattern (more than a few residents). CMS level K.

    Health citation F-0867, Administration Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 24, 2023).

  3. No harm, with potential for more than minimal harm

    Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

    Widespread (many residents). CMS level F.

    Health citation F-0812, Nutrition and Dietary Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 24, 2023).

  4. No harm, with potential for more than minimal harm

    Develop and maintain an Emergency Preparedness Program (EP).

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0004, Emergency Preparedness Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 26, 2023).

  5. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 26, 2023).

  6. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 26, 2023).

  7. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 26, 2023).

  8. No harm, with potential for more than minimal harm

    Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

    Widespread (many residents). CMS level F.

    Health citation F-0812, Nutrition and Dietary Deficiencies. Inspection of October 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 28, 2019).

  9. No harm, with potential for more than minimal harm

    Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.

    Widespread (many residents). CMS level F.

    Health citation F-0812, Nutrition and Dietary Deficiencies. Inspection of October 11, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 15, 2018).

  10. No harm, with potential for more than minimal harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0222, Egress Deficiencies. Inspection of October 11, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 5, 2018).

  11. No harm, with potential for more than minimal harm

    Have corridors or aisles that are unobstructed and are at least 8 feet in width.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0232, Egress Deficiencies. Inspection of October 11, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 18, 2018).

  12. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of October 11, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 21, 2018).

  13. No harm, with potential for more than minimal harm

    Provide care and assistance to perform activities of daily living for any resident who is unable.

    Pattern (more than a few residents). CMS level E.

    Health citation F-0677, Quality of Life and Care Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 24, 2023).

  14. No harm, with potential for more than minimal harm

    Have corridors or aisles that are unobstructed and are at least 8 feet in width.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0232, Egress Deficiencies. Inspection of October 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 4, 2019).

  15. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of October 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 4, 2019).

  16. No harm, with potential for more than minimal harm

    Have restrictions on the use of portable space heaters.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0781, Miscellaneous Deficiencies. Inspection of October 11, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 22, 2018).

  17. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of October 11, 2018. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 1, 2018).

  18. No harm, with potential for more than minimal harm

    Provide appropriate care for residents who are continent or incontinent of bowel/bladder, appropriate catheter care, and appropriate care to prevent urinary tract infections.

    Isolated (one or a few residents). CMS level D.

    Health citation F-0690, Quality of Life and Care Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 24, 2023).

  19. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 26, 2023).

  20. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0511, Services Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 26, 2023).

  21. No harm, with potential for more than minimal harm

    Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0741, Miscellaneous Deficiencies. Inspection of July 26, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (August 26, 2023).

  22. No harm, with potential for more than minimal harm

    Provide and implement an infection prevention and control program.

    Isolated (one or a few residents). CMS level D.

    Health citation F-0880, Infection Control Deficiencies. Inspection of October 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 28, 2019).

  23. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of October 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 4, 2019).

  24. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of October 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 4, 2019).

  25. No harm, with potential for more than minimal harm

    Install smoke barrier doors that can resist smoke for at least 20 minutes.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0374, Smoke Deficiencies. Inspection of October 24, 2019. Found during a standard inspection.

    The home gave a date the problem would be corrected (December 4, 2019).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.