All citations for Heritage Pointe of Warren

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Heritage Pointe of Warren

Last standard health inspection on record

April 13, 2026

Showing 1 to 12 of 12 citations

  1. No harm, with potential for more than minimal harm

    Conduct testing and exercise requirements.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0039, Emergency Preparedness Deficiencies. Inspection of February 26, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 1, 2025).

  2. No harm, with potential for more than minimal harm

    Conduct testing and exercise requirements.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0039, Emergency Preparedness Deficiencies. Inspection of March 11, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2024).

  3. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of March 11, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2024).

  4. No harm, with potential for more than minimal harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0222, Egress Deficiencies. Inspection of February 26, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 1, 2025).

  5. No harm, with potential for more than minimal harm

    Conform to length requirements for dead end corridors.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0251, Egress Deficiencies. Inspection of February 26, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 1, 2025).

  6. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of February 26, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 1, 2025).

  7. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of March 11, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2024).

  8. No harm, with potential for more than minimal harm

    Add doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0222, Egress Deficiencies. Inspection of March 11, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2024).

  9. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of March 11, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2024).

  10. No harm, with potential for more than minimal harm

    Ensure that waiting areas, nurse’s stations, gift shops, and cooking facilities, open to the corridor are properly protected.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0361, Smoke Deficiencies. Inspection of March 11, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2024).

  11. No harm, with potential for more than minimal harm

    Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0741, Miscellaneous Deficiencies. Inspection of March 11, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2024).

  12. No harm, with potential for minimal harm

    Establish staff and initial training requirements.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0037, Emergency Preparedness Deficiencies. Inspection of February 26, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 1, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.