All citations for Heritage Square Healthcare Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Heritage Square Healthcare Center

Last standard health inspection on record

May 8, 2025

Showing 1 to 11 of 11 citations

  1. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 5, 2025).

  2. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of December 21, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 20, 2023).

  3. No harm, with potential for more than minimal harm

    Properly provide smoke detection systems in areas open to corridors.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0347, Smoke Deficiencies. Inspection of May 8, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 5, 2025).

  4. No harm, with potential for more than minimal harm

    Have an alternate power supply for its alarm system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0344, Smoke Deficiencies. Inspection of March 14, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 19, 2024).

  5. No harm, with potential for more than minimal harm

    Properly provide smoke detection systems in areas open to corridors.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0347, Smoke Deficiencies. Inspection of March 14, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 19, 2024).

  6. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of December 21, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 20, 2023).

  7. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of December 21, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 20, 2023).

  8. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of December 21, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 20, 2023).

  9. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of December 21, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 20, 2023).

  10. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of December 21, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 20, 2023).

  11. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of December 21, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (January 20, 2023).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.