Immediate jeopardy to resident health or safety
Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.
The home gave a date the problem would be corrected (June 29, 2024).
No harm, with potential for more than minimal harm
Have a registered nurse on duty 8 hours a day; and select a registered nurse to be the director of nurses on a full time basis.
The home gave a date the problem would be corrected (May 8, 2026).
No harm, with potential for more than minimal harm
Conduct risk assessment and an All-Hazards approach.
The home gave a date the problem would be corrected (May 8, 2026).
No harm, with potential for more than minimal harm
Conduct testing and exercise requirements.
The home gave a date the problem would be corrected (May 8, 2026).
No harm, with potential for more than minimal harm
Ensure smoke barriers are constructed to a 1 hour fire resistance rating.
The home gave a date the problem would be corrected (May 8, 2026).
No harm, with potential for more than minimal harm
Procure food from sources approved or considered satisfactory and store, prepare, distribute and serve food in accordance with professional standards.
The home gave a date the problem would be corrected (March 24, 2023).
No harm, with potential for more than minimal harm
Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.
The home gave a date the problem would be corrected (March 24, 2023).
No harm, with potential for more than minimal harm
Install emergency lighting that can last at least 1 1/2 hours.
The home gave a date the problem would be corrected (March 24, 2023).
No harm, with potential for more than minimal harm
Provide properly protected cooking facilities.
The home gave a date the problem would be corrected (March 24, 2023).
No harm, with potential for more than minimal harm
Have approved installation, maintenance and testing program for fire alarm systems.
The home gave a date the problem would be corrected (March 24, 2023).
No harm, with potential for more than minimal harm
Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.
The home gave a date the problem would be corrected (March 24, 2023).
No harm, with potential for more than minimal harm
Have generator or other power source capable of supplying service within 10 seconds.
The home gave a date the problem would be corrected (March 24, 2023).
No harm, with potential for more than minimal harm
Provide and implement an infection prevention and control program.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Use approved construction type or materials.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Have properly located and lighted "Exit" signs.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Install a fire alarm system that can be heard throughout the facility.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Have approved installation, maintenance and testing program for fire alarm systems.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Install an approved automatic sprinkler system.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Inspect, test, and maintain automatic sprinkler systems.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Provide a written emergency evacuation plan.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Have simulated fire drills held at unexpected times.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Have generator or other power source capable of supplying service within 10 seconds.
The home gave a date the problem would be corrected (March 11, 2020).
No harm, with potential for more than minimal harm
Have proper medical gas storage and administration areas.
The home gave a date the problem would be corrected (March 11, 2020).
Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.