All citations for Kern River Transitional Care

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Kern River Transitional Care

Last standard health inspection on record

April 24, 2025

Showing 1 to 18 of 18 citations

  1. No harm, with potential for more than minimal harm

    Provide emergency officials' contact information.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0031, Emergency Preparedness Deficiencies. Inspection of April 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 2, 2025).

  2. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of April 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 1, 2025).

  3. No harm, with potential for more than minimal harm

    Implement emergency and standby power systems.

    Pattern (more than a few residents). CMS level E.

    Emergency preparedness citation E-0041, Emergency Preparedness Deficiencies. Inspection of May 13, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2021).

  4. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of April 24, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 1, 2025).

  5. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 7, 2024).

  6. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 7, 2024).

  7. No harm, with potential for more than minimal harm

    Meet other general requirements that are deficient.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0500, Services Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 7, 2024).

  8. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 7, 2024).

  9. No harm, with potential for more than minimal harm

    Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0901, Electrical Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 7, 2024).

  10. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 7, 2024).

  11. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 7, 2024).

  12. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of May 13, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2021).

  13. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 13, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2021).

  14. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of May 13, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2021).

  15. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of May 13, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2021).

  16. No harm, with potential for more than minimal harm

    Meet requirements for the use of electrical equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0919, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 13, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2021).

  17. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 13, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2021).

  18. No harm, with potential for more than minimal harm

    Have proper medical gas storage and administration areas.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0923, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 13, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2021).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.