All citations for Kittanning Health & Rehab Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Kittanning Health & Rehab Center

Last standard health inspection on record

January 9, 2026

Showing 1 to 25 of 37 citations

  1. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of January 9, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 9, 2026).

  2. No harm, with potential for more than minimal harm

    Establish emergency prep training and testing.

    Widespread (many residents). CMS level F.

    Emergency preparedness citation E-0036, Emergency Preparedness Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  3. No harm, with potential for more than minimal harm

    Meet other general requirements.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0100, Construction Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  4. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  5. No harm, with potential for more than minimal harm

    Have properly located and lighted "Exit" signs.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0293, Egress Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  6. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  7. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  8. No harm, with potential for more than minimal harm

    Have simulated fire drills held at unexpected times.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0712, Miscellaneous Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  9. No harm, with potential for more than minimal harm

    Have power receptacles that are properly grounded.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0912, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  10. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  11. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of February 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 15, 2024).

  12. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of February 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 5, 2024).

  13. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of February 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 15, 2024).

  14. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of January 9, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 9, 2026).

  15. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 9, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 9, 2026).

  16. No harm, with potential for more than minimal harm

    Conduct testing and exercise requirements.

    Pattern (more than a few residents). CMS level E.

    Emergency preparedness citation E-0039, Emergency Preparedness Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  17. No harm, with potential for more than minimal harm

    Keep aisles, corridors, and exits free of obstruction in case of emergency.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0211, Egress Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  18. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  19. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 2, 2025).

  20. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 15, 2024).

  21. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of January 16, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 21, 2025).

  22. No harm, with potential for more than minimal harm

    Have properly located and lighted "Exit" signs.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0293, Egress Deficiencies. Inspection of February 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 15, 2024).

  23. No harm, with potential for more than minimal harm

    Properly provide smoke detection systems in areas open to corridors.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0347, Smoke Deficiencies. Inspection of February 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 5, 2024).

  24. No harm, with potential for more than minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of February 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 15, 2024).

  25. No harm, with potential for minimal harm

    Conduct risk assessment and an All-Hazards approach.

    Widespread (many residents). CMS level C.

    Emergency preparedness citation E-0006, Emergency Preparedness Deficiencies. Inspection of January 9, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 9, 2026).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.