All citations for Lebanon Skilled Nursing and Rehabilitation Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Lebanon Skilled Nursing and Rehabilitation Center

Last standard health inspection on record

April 17, 2026

Showing 1 to 11 of 11 citations

  1. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of March 26, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 30, 2025).

  2. No harm, with potential for more than minimal harm

    Provide properly sized and located linen or trash receptacles.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0754, Miscellaneous Deficiencies. Inspection of March 26, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 30, 2025).

  3. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of April 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 29, 2024).

  4. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of April 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 29, 2024).

  5. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 19, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 8, 2023).

  6. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of May 19, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 8, 2023).

  7. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0511, Services Deficiencies. Inspection of May 19, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 8, 2023).

  8. No harm, with potential for minimal harm

    Meet other general requirements.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0100, Construction Deficiencies. Inspection of April 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 29, 2024).

  9. No harm, with potential for minimal harm

    Properly provide smoke detection systems in areas open to corridors.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0347, Smoke Deficiencies. Inspection of April 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 29, 2024).

  10. No harm, with potential for minimal harm

    Properly select, install, inspect, or maintain portable fire extinguishes.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0355, Smoke Deficiencies. Inspection of April 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 29, 2024).

  11. No harm, with potential for minimal harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0914, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of April 12, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 29, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.