All citations for Park Ridge Nursing Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Park Ridge Nursing Center

Last standard health inspection on record

March 19, 2026

Showing 1 to 8 of 8 citations

  1. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 28, 2024).

  2. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 21, 2024).

  3. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 23, 2024).

  4. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 21, 2024).

  5. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 15, 2026).

  6. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 15, 2026).

  7. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of March 19, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (April 15, 2026).

  8. No harm, with potential for more than minimal harm

    Ensure that testing and maintenance of electrical equipment is performed.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0921, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 16, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 3, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.