All citations for Rolling Hills Rehab Ctr

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Rolling Hills Rehab Ctr

Last standard health inspection on record

May 21, 2026

Showing 1 to 11 of 11 citations

  1. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of May 21, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 22, 2026).

  2. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of May 21, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 10, 2026).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of January 11, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (February 5, 2024).

  4. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of May 21, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 22, 2026).

  5. No harm, with potential for more than minimal harm

    Have power receptacles that are properly grounded.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0912, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 21, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 9, 2026).

  6. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0521, Services Deficiencies. Inspection of May 21, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 21, 2026).

  7. No harm, with potential for more than minimal harm

    Ensure proper usage of power strips and extension cords.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0920, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 21, 2026. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 8, 2026).

  8. No harm, with potential for more than minimal harm

    Establish an Emergency Preparedness Program (EP).

    Isolated (one or a few residents). CMS level D.

    Emergency preparedness citation E-0001, Emergency Preparedness Deficiencies. Inspection of February 20, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 18, 2025).

  9. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of February 20, 2025. Found during a standard inspection.

    A waiver was granted (March 18, 2025).

  10. No harm, with potential for more than minimal harm

    Have power receptacles that are properly grounded.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0912, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 20, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 18, 2025).

  11. No harm, with potential for more than minimal harm

    Ensure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0914, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of February 20, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (March 18, 2025).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.