All citations for Shore Health & Rehab Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Shore Health & Rehab Center

Last standard health inspection on record

July 26, 2024

This is more than 2 years ago. Newer inspection results may not be on record yet, so the results below may not describe the home today. Ask the home for its most recent inspection report.

Showing 1 to 10 of 10 citations

  1. No harm, with potential for more than minimal harm

    Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0223, Egress Deficiencies. Inspection of July 26, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 12, 2024).

  2. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of July 26, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 12, 2024).

  3. No harm, with potential for more than minimal harm

    Provide properly protected cooking facilities.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0324, Smoke Deficiencies. Inspection of July 26, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 12, 2024).

  4. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of July 26, 2024. Found during a standard inspection.

    A waiver was granted (January 8, 2025).

  5. No harm, with potential for more than minimal harm

    Have a battery powered remote alarm panel in a location accessible by operating personnel.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0916, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of July 26, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 12, 2024).

  6. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of March 12, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 5, 2021).

  7. No harm, with potential for more than minimal harm

    Install an approved automatic sprinkler system.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0351, Smoke Deficiencies. Inspection of March 12, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 5, 2021).

  8. No harm, with potential for more than minimal harm

    Ensure that waiting areas, nurse’s stations, gift shops, and cooking facilities, open to the corridor are properly protected.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0361, Smoke Deficiencies. Inspection of March 12, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 5, 2021).

  9. No harm, with potential for more than minimal harm

    Have properly installed electrical wiring and gas equipment.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0511, Services Deficiencies. Inspection of March 12, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 5, 2021).

  10. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of March 12, 2021. Found during a standard inspection.

    The home gave a date the problem would be corrected (May 5, 2021).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.