All citations for Springdale Health and Rehabilitation Center
State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.
Last standard health inspection on record
February 13, 2026
Showing 1 to 14 of 14 citations
No harm, with potential for more than minimal harm
Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Have an alternate power supply for its alarm system.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Inspect, test, and maintain automatic sprinkler systems.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Properly select, install, inspect, or maintain portable fire extinguishes.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Install corridor and hallway doors that block smoke.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Have posted "No-smoking" signs in areas where smoking is not permitted or ashtrays provided where smoking was allowed.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Ensure proper usage of power strips and extension cords.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Meet requirements for the use and maintenance of medical gas equipment.
The home gave a date the problem would be corrected (March 15, 2026).
No harm, with potential for more than minimal harm
Conduct testing and exercise requirements.
The home gave a date the problem would be corrected (August 31, 2024).
No harm, with potential for more than minimal harm
Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.
The home gave a date the problem would be corrected (August 31, 2024).
No harm, with potential for more than minimal harm
Properly provide smoke detection systems in areas open to corridors.
The home gave a date the problem would be corrected (August 31, 2024).
No harm, with potential for more than minimal harm
To conduct inspection, testing and maintenance of fire doors by qualified individuals.
The home gave a date the problem would be corrected (August 31, 2024).
No harm, with potential for more than minimal harm
Provide exit doors that are held open by devices that will automatically close on the activation of a fire alarm or smoke detector.
The home gave a date the problem would be corrected (August 25, 2023).
Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of October 1, 2026. Inspection results describe the home at the time of each inspection.