All citations for St. Ann's Community

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to St. Ann's Community

Last standard health inspection on record

September 10, 2025

Showing 1 to 12 of 12 citations

  1. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of September 10, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 10, 2025).

  2. No harm, with potential for more than minimal harm

    To conduct inspection, testing and maintenance of fire doors by qualified individuals.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0761, Miscellaneous Deficiencies. Inspection of May 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 5, 2024).

  3. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of May 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 5, 2024).

  4. No harm, with potential for more than minimal harm

    Install corridor and hallway doors that block smoke.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0363, Smoke Deficiencies. Inspection of August 29, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 21, 2022).

  5. No harm, with potential for more than minimal harm

    Ensure heating and ventilation systems that have been properly installed according to the manufacturer's instructions.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0521, Services Deficiencies. Inspection of August 29, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 21, 2022).

  6. No harm, with potential for more than minimal harm

    Have elevators that firefighters can control in the event of a fire.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0531, Services Deficiencies. Inspection of August 29, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 21, 2022).

  7. No harm, with potential for more than minimal harm

    Have generator or other power source capable of supplying service within 10 seconds.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0918, Gas, Vacuum, and Electrical Systems Deficiencies. Inspection of August 29, 2022. Found during a standard inspection.

    The home gave a date the problem would be corrected (October 21, 2022).

  8. No harm, with potential for more than minimal harm

    Install emergency lighting that can last at least 1 1/2 hours.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0291, Egress Deficiencies. Inspection of September 10, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 10, 2025).

  9. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of September 10, 2025. Found during a standard inspection.

    The home gave a date the problem would be corrected (November 10, 2025).

  10. No harm, with potential for more than minimal harm

    Have stairways and smokeproof enclosures used as exits that meet safety requirements.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0225, Egress Deficiencies. Inspection of May 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 5, 2024).

  11. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of May 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 5, 2024).

  12. No harm, with potential for minimal harm

    Ensure that building systems meet requirements determined by risk assessment procedures performed by qualified personnel.

    Widespread (many residents). CMS level C.

    Fire safety citation K-0901, Electrical Deficiencies. Inspection of May 8, 2024. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 5, 2024).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.