All citations for Stonehill Care Center

State inspectors check nursing homes that take Medicare or Medicaid against federal rules, usually about once a year, and also look into complaints. Each rule a home did not meet is a citation.

Back to Stonehill Care Center

Last standard health inspection on record

August 7, 2025

Showing 1 to 10 of 10 citations

  1. No harm, with potential for more than minimal harm

    Have a complete alarm system manually initiated and initiated by fire sprinkler system connection.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0342, Smoke Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (July 7, 2023).

  2. No harm, with potential for more than minimal harm

    Have approved installation, maintenance and testing program for fire alarm systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0345, Smoke Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 16, 2023).

  3. No harm, with potential for more than minimal harm

    Inspect, test, and maintain automatic sprinkler systems.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0353, Smoke Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 16, 2023).

  4. No harm, with potential for more than minimal harm

    Provide a written emergency evacuation plan.

    Widespread (many residents). CMS level F.

    Fire safety citation K-0711, Miscellaneous Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 16, 2023).

  5. No harm, with potential for more than minimal harm

    Meet requirements for sections of health care facilities separated by fire resistive construction.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0131, Construction Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 16, 2023).

  6. No harm, with potential for more than minimal harm

    Ensure that special areas are constructed so that walls can resist fire for one hour or have an approved fire extinguishing system.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0321, Smoke Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 19, 2023).

  7. No harm, with potential for more than minimal harm

    Ensure smoke barriers are constructed to a 1 hour fire resistance rating.

    Pattern (more than a few residents). CMS level E.

    Fire safety citation K-0372, Smoke Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 16, 2023).

  8. No harm, with potential for more than minimal harm

    Develop and implement a complete care plan that meets all the resident's needs, with timetables and actions that can be measured.

    Isolated (one or a few residents). CMS level D.

    Health citation F-0656, Resident Assessment and Care Planning Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 27, 2023).

  9. No harm, with potential for more than minimal harm

    Ensure that a nursing home area is free from accident hazards and provides adequate supervision to prevent accidents.

    Isolated (one or a few residents). CMS level D.

    Health citation F-0689, Quality of Life and Care Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 27, 2023).

  10. No harm, with potential for more than minimal harm

    Use approved construction type or materials.

    Isolated (one or a few residents). CMS level D.

    Fire safety citation K-0161, Construction Deficiencies. Inspection of June 8, 2023. Found during a standard inspection.

    The home gave a date the problem would be corrected (June 16, 2023).

Source: CMS Provider Information, Fire Safety Deficiencies, Health Deficiencies, Citation Code Look-up, data as of September 30, 2026. Inspection results describe the home at the time of each inspection.